The seal was fitted properly and the door closes the way it should now. The visit ran late enough that I had to rearrange my afternoon, and a call to warn me would have been worth a great deal.
Lachlan B.2026-09-20
Independent Sub-Zero specialists · Fleming Island, Clay County
Monday – Friday 8:00am – 6:00pm Call (904) 201-3304
Rated 4.3 out of 5 across 62 customer reviews. The 24 below are printed in full and chosen to cover every kind of work and every shore we drive to; the others appear three at a time on the service and place pages, beside the work they describe.
The figure above is not a claim. It is the mean of all 62 entries in the pool, worked to one decimal place. Nothing is held back to flatter it: the lukewarm entries and the outright critical ones are counted, and several are in the selection below. A shop that has never had a part arrive late is a shop nobody has ever called.
Each entry describes one fault on one cabinet — what the owner noticed, what was measured, what was changed and how the call ended. Reading how somebody else's warm compartment turned out is more use than a paragraph of praise. Names appear as a first name and a last initial.
No entry quotes a figure. What a visit costs is set out on the pricing page, where it can be checked against the invoice, and what is covered afterwards is on the warranty page. If an entry below sounds like your own cabinet, the page for that work explains how the fault is narrowed down.
Sub-Zero builds refrigeration and nothing else, so nothing on this page describes any other kind of appliance. Hibernia Cold Systems is independent, and no entry below says otherwise.
The seal was fitted properly and the door closes the way it should now. The visit ran late enough that I had to rearrange my afternoon, and a call to warn me would have been worth a great deal.
Lachlan B.2026-09-20
Cubes were small and the bin never filled properly. He put a probe in the compartment first and found it sitting warmer than the machine needs, so what he replaced was a fan and not the module.
Emrys G.2026-09-18
Upper shelves had crept above the setting while the bottom of the cabinet was fine. He cleaned a condenser thick with dust left by our flooring work, and the drift closed up again over the next day.
Ferdinand A.2026-09-16
He gauged the system, found it low, and was straight with us that a leak found once can be found again. We agreed to the work knowing that, and it has held temperature since he weighed the charge in.
Rowan F.2026-09-15
The bin was filling at half the speed it used to. He measured pressure at the valve, found it weak, and traced that to a supply line kinked behind the cabinet the last time it was pushed back in.
Beatrix H.2026-09-12
Ice was building along the top of the drawer opening. He found the seal on the upper drawer sitting proud where it had been pinched, refitted it properly, and the icing has not come back since.
Tobias K.2026-09-11
Our refrigerator column was running far longer than it used to. He cleaned a condenser loaded with pollen and oak litter, then rechecked the compartment with a probe instead of reading the front display.
Horace K.2026-09-09
Frost kept returning on the freezer wall within days of my clearing it. He showed me the seal letting go along one whole side with a sheet of paper, which was difficult to argue with.
Jasper L.2026-09-07
The work itself was careful and the unit is properly cold now. It took three appearances at the house to finish, and the reason for that was never explained to me in a way I could follow.
Petra M.2026-09-05
Our built-in had become loud enough to hear from the porch. He measured the current the condenser fan was drawing, showed me on the meter that it was dragging, and had the correct motor with him.
Sylvana B.2026-09-02
The glass door fogged every humid afternoon and water was collecting on the lowest rack. The catch had gone out of adjustment so the door never drew fully in. He set it and fitted a new seal.
Sorrel J.2026-09-01
The beverage unit in our butler pantry had stopped cooling. He was honest that the cabinet it sits in has almost no air, repaired the fan anyway, and told us to keep the toe vent clear if we want it to last.
Greta P.2026-08-31
Cabinet ran without ever getting down to its setting. Before touching the sealed side he cleared a silted condenser and rechecked, which changed nothing, so the diagnosis was earned rather than assumed.
Cassius D.2026-08-29
The drawers in our island were cool rather than cold. He took the front off, cleared an air path packed solid with dust, and measured the compartment again an hour later before calling it done.
Rowena E.2026-08-27
Interior lighting had gone dim and the door no longer drew itself in. Both came back to one harness at the hinge that had chafed through. He repaired it rather than selling us a door assembly.
Imogen T.2026-08-25
The display was showing an alarm and I could not tell whether the wine was at risk. He read the stored history, found nothing wrong with the sealed side, and replaced a sensor that had drifted.
Maxine V.2026-08-23
No ice at all after a long weekend away. He warmed out a frozen fill tube, then spent longer finding why it had frozen than clearing it, and the answer was a door that had stopped pulling in at the base.
Ottoline C.2026-08-21
Water had been sitting under the crisper drawers for a month. He melted out the drain, refitted the clip that holds the warming loop against the tube, and told me what to watch for if it returns.
Everard P.2026-08-19
Our door had started catching on the cabinetry as it swung. He found the hinge had taken a set under the weight of the panel, fitted new hardware and checked the swing against the island before leaving.
Susanna W.2026-08-16
The freezer column had stopped holding and the panel front was sweating. He traced the air path behind the joinery, found the return closed off by a filler strip fitted tight, and opened it back up.
Delphine A.2026-08-14
The cabinet was holding a few degrees warm on the upper side and I had assumed the worst. He checked the air damper and the evaporator before saying a word about the sealed side, and it was the damper motor.
Thomasina R.2026-08-11
The seal had gone hard along the top and the cabinet face was damp every afternoon. New gasket, hinge shimmed, closer reset, and the paper test held everywhere he tried it before he packed up.
Verity N.2026-08-08
The repair holds and the cabinet is quiet again. What I did not care for was being told the part would arrive at the start of the week and then hearing nothing at all until I chased it myself.
Marcus O.2026-08-06
The compressor was cutting out on its overload every few minutes. He measured the windings and the start components in front of me and explained what each reading meant before quoting anything.
Augustin S.2026-08-02